apple green fraxel skin cooling cellulite treatment cavitational ultrasound radiofrequency wrinkles magnetotherapy physical therapy medical equipments endodermic massage electrolipolysis lymphatic drainage pressure kotz  electrotherapy ipl epilation photo rejuvination cellular activator iontophoresis sound muscle stimulator laser surgery diode co2 beauty equipments  
BOOSTER SP
apple green fraxel skin cooling cellulite treatment cavitational ultrasound radiofrequency wrinkles magnetotherapy physical therapy medical equipments endodermic massage electrolipolysis lymphatic drainage pressure kotz  electrotherapy ipl epilation photo rejuvination cellular activator iontophoresis sound muscle stimulator laser surgery diode co2 beauty equipments



Chirurghischer Booster SP

Impulslaser zu 30 W mit CO2 versiegelte Quelle.

Entwickelt aus eine enge Zusammenarbeit mit bekannten Fachärzte der Branche, Booster SP ist ein äußerst vielseitiger und zuverlässiger Laser entstanden, der die Ansprüche jeglicher chirurgische Technik erfüllt.
  
Booster SP ist gänzlich von einem Mikroprozessor kontrolliert. Er stellt sich, dank der hohen Technologie, als ein Gerät, der sehr einfach zu bedienen ist.

Er hat ein mäßiges Gewicht. Mit seiner schönen und essentiellen Form, und seiner beschränkten Ausmaß passt leicht und angenehm in einer Praxis oder in einer OP.  


Download depliant apple green fraxel skin cooling cellulite treatment cavitational ultrasound radiofrequency wrinkles magnetotherapy physical therapy medical equipments endodermic massage electrolipolysis lymphatic drainage pressure kotz  electrotherapy ipl epilation photo rejuvination cellular activator iontophoresis sound muscle stimulator laser surgery diode co2 beauty equipments

Surgical laser

- Laser source type: CO2 Sealed Off
- Wavelngth: 10,6 um
- Divergence: <2 mrad
- Laser beam diam. at source: 4 mm
- Emission: Continuous – Pulsed - Superpulsed
- Output power from source 25 W
- Output power on tissue 20 W
- Peack power (Superpulse) 90 W
- Emission mode: Continuous - Single impulse - Repeated imp. (Pause 0,35)
- Power control: From 0,5 W to Max (Step O,5 W)
- Exposure control: From 50 to 950 mS (Step 50mS)
- Impulses frequency control: From 1 to 2000 Hz
- Duty cicle control: From 1% to 50%
- Beam optical path: Self balanced surgical arm with 7 mirrors
- Standard surgical probe: Focal 2"(50mm) – Spot 0,125 mm
- Probe on request: Focal 38mm – 63mm – 127mm
- System controls in real time: Controlled by microprocessor
- Cooling: Closed circuit with air\water exchanger
- Pilot beam type: Diode
- Pilot beam emission: Continuous
- Pilot beam
wavelength 630 nm
- Pilot beam power 3mW with 3 position actenuator
- Divergence: 1 mrad
- Laser beam diam. at source: 2mm
- Supply: 230V-50 Hz – 1000 VA
- Dimensions (arm included): mm 400x400x1600(h)
- Weight: kg 40
- Classification: Class I type B (IEC 601-1)
- Comply with: