PULSAR:
scanning soft laser with double emission IR+R for taking advantage
from the synergic effect.
The
LASER beam special features (it is monochromatic, coherent, brilliant,
directional) make it different from any other light source.
These
features are responsible for the well-known biological effect of the
LASER.
A
number of researches led by several authors together with numerous
studies still in progress tend to demonstrate the main effect of the
LASER, the biostimulation, which helps the normal cellular reconstruction
with ATP increase.
Several
authors demontrated a few major effects produced by the LASER, like:
-
early disappearance of pain symptomatology;
-
quick resolution of oedermas;
acceleration
of scarring and antiflammatory processes.
PULSAR
In
particular, in the pathology of the locomotive apparatus following
treatment with LASER, interruption of the triad <<oedema-contracture-pain>>
is noticed, with objective improvement of the symptomatology as the
applications progress.
PULSAR
operates in the spectrumrange included between 0.6 and 1.1 micron
(red near infrared), therefore che capacity of penetration in the
tissues treated is particularly high. The HeNe laser esplicates out
all its activity in the first layers of the skin, while the radiation
IR reaches a deep penetration varying from 1 to 3 cm, depemding on
the tissue constitution (karatin, melanin, hemoglobin and caroten
condition the absorption of laser radiations).
Depending
on the frequencies and the exposure times used, a wide variety of
diseases can be treated:
-
pathology of the locomotive apparatus: tendinitis, distorsion, strains,
etc.;
-
pathology of the osteoarticular apparatus: arthrosis, periarthritis,
etc.;
-
rhinitis, sinisitis, otitis, etc.; in otoiatrics
-
cellulitis, cheloidis, rhagades, etc.; in dermatology
-
vaginitis, vulvitis, etc. in gynaecology
-
Download depliant
TECHNICAL
SPECIFICATIONS
SCANNER
LASER IR R
-
Elegant equipment on telescopic bearing constituted by a HeNe tube,
four IR GaAS diodes setted in line with HeNe and an external IR probe
-
R maximum power: 5 nW
-
Beam divergence: 2 mrad
-
IR scanning laser power:3W
-
Modulation: 0,5-160 Hz
-
Scanning: XY
-
Program antalgici
-
Digital dispay of the time
-
Test device of IR laser output by means of a sensor
-
Scanning line inversion
-
Power supply: 230 V - 50/60 Hz - 150 W
-
Dimensions: 700 x 450 x 1750 mm
-
Weight: Kg 35
NORME
DI SICUREZZA
CEI 62.5 - CEI 76.1 - CEI 76.2 - IEC 601.1 - IEC 820 - IEC 825 -CE
89336 - CE 0476